LUNA-III™ 자동 셀카운터는 고급 알고리즘, 정밀 자동 초점, 재사용 가능한 슬라이드, 무독성 염료, 네트워크 액세스, 재분석 옵션, 컴팩트하고 사용자 친화적인 디자인으로 탁월한 정확도를 제공합니다.
실험실의 생산성과 정밀도를 향상시키도록 설계된 궁극의 세포 계수 기술인 LUNA-III™ 자동 셀카운터를 소개합니다. LUNA-II™의 입증된 성공을 바탕으로 LUNA-III™ 자동 셀카운터는 다양한 고급 기능을 제공합니다.
Easy to use and adjust parameters for different sample types. Easy to use instrument with a small footprint. It is easy to change parameters for the most accurate cell counting for different cell types. Disposable cell counting slides allow for the rapid counting of many different cultures with easy clean-up. Customer service is also great.
Cornell University
Quick and easy – makes cell culture a breeze! Our lab relies heavily on the Luna – it’s quick and easy to use, and I know it will give me an accurate count! It’s particularly great when I’m short on time because I can simply load the settings for a protocol that I’ve created previously and then I can count multiple samples efficiently. I manually adjust the focus to get the best and most accurate results, but the interface is clear and easy to use. All of our lab members use this piece of equipment daily, and it makes a huge impact on the l ab while taking up minimal benchtop space. We highly recommend the Luna!
Boston University
Overexpression of MMPs, cytokines, and RANKL/OPG in temporomandibular joint osteoarthritis and their association with joint pain, mouth opening, and bone degeneration: A preliminary report.
2021. Cafferata EA, Monasterio G, Castillo F, Carvajal P, Flores G, Díaz W, Fuentes AD, Vernal R. Oral diseases 27(4):970–980.
Aryl Hydrocarbon Receptor is Involved in the Proinflammatory Cytokine Response to Cadmium.
2021. Kulas J, Tucovic D, Zeljkovic M, Popovic D, Popov Aleksandrov A, Kataranovski M, Mirkov I. Biomedical and Environmental Sciences 34(3):192-202.
Inertial Microfluidics-Based Separation of Microalgae Using a Contraction–Expansion Array Microchannel.
2021. Kim GY, Son J, Han JI, Park JK. Micromachines (Basel) 12(1):97.
Mitochondrial pyruvate carrier 1 regulates ferroptosis in drug-tolerant persister head and neck cancer cells via epithelial-mesenchymal transition.
2021. You JH, Lee J, Roh JL. Cancer Letters 507:40–54.
Interplay Between Nanoplastics and the Immune System of the Mediterranean Sea Urchin Paracentrotus lividus.
2021. Murano C, Bergami E, Liberatori G, Palumbo A, Corsi I. Frontiers in Marine Science https://doi.org/10.3389/fmars.2021.647394.
Cat # | Product | Qty |
---|---|---|
L60001 | LUNA-III™ Automated Cell Counter | 1 unit |
L60002 | LUNA-III™ Automated Cell Counter, Sustainable Package | 1 unit |
L12001 | LUNA™ Cell Counting Slides, 50 Slides | 1 boxes |
L12002 | LUNA™ Cell Counting Slides, 500 Slides | 10 boxes |
L12003 | LUNA™ Cell Counting Slides, 1000 Slides | 20 boxes |
L12011 | LUNA™ Reusable Slide | 1 unit |
L12012 | LUNA™ Reusable Slides (2 pack) | 2 units |
L12014 | LUNA™ Reusable Slide Coverslips | 10 units |
T13001 | Trypan Blue Stain, 0.4% | 2 x 1 mL |
T13011 | Trypan Blue Stain, 0.4%, Sterile-filtered | 2 x 1 mL |
L13002 | Erythrosin B Stain | 2 x 1 mL |
B13101 | LUNA™ Standard Beads | 2 X 1 mL |
P17001 | LUNA™ Printer II | 1 unit |
U10005 | USB Drive, 16 GB | 1 unit |
L72041 | Cell Counter Validation Slide-BF II | 1 unit |
L64003 | LUNA-III™ IQ/OQ Protocol | 1 copy |
Cell Counting Time | Approx. 10 s (manual focusing) Approx. 15 s (autofocusing) |
Cell Concentration Range | 5×104 – 1×107 cells/ml |
Cell Size Range | 3~60 μm (optimal : 8~30 μm) |
Cell Viability Range | 0~100 % |
Image Resolution | 5 MP |
Image Type | TIF, annotated TIF |
Report | PDF format |
Dimensions (W×D×H) | 16 × 18 × 28 cm (6.3 × 7.0 × 11.0 in) |
Weight | 1.8 kg (4 lb) *without the AC adaptor and power cord |
Operating Power | 100~240 VAC, 1.2 A |
Frequency | 50/60 Hz |
Electrical Input | 12 VDC, 3.3 A |