BRIGHTFIELD CELL COUNTER
LUNA-III™ Compteur automatique de cellules

The LUNA-III™ Automated Cell Counter provides unmatched accuracy with advanced algorithms, precise autofocusing, reusable slides, non-toxic dyes, network access, re-analysis options, and a compact, user-friendly design.

Demander un devis ou une démonstration
Comparer les compteurs

Introducing the LUNA-III™ Automated Cell Counter, the ultimate in cell counting technology, designed to enhance your lab's productivity and precision. Building on the proven success of the LUNA II™, the LUNA-III™ Automated Cell Counter offers an array of advanced features:

Apprentissage automatique (Machine Learning) optimisé pour l'excellence
Experience unparalleled accuracy for individual cell recognition in highly aggregated samples, thanks to our state-of-the-art algorithms.
Technologie de mise au point automatique avancée
Un autofocus rapide et précis pour une efficacité améliorée. Les capacités de mise au point automatique améliorées améliorent la reconnaissance et la mesure des cellules, permettant de meilleures décisions dans les applications et protocoles en aval.
Précision optimale par réanalyse
Obtenez des résultats précis pour divers types de cellules et des capacités de réanalyse distinctives permettant aux utilisateurs d'affiner les protocoles, donc de préserver les échantillons et d'éliminer toute préparation supplémentaire.
Gestion transparente et flexible des données
Bénéficiez d'une gestion transparente des données grâce au stockage interne, la prise en charge via clé USB et une connectivité réseau, permettant un stockage, une récupération et un transfert faciles des données vers des ordinateurs.
Options écologiques
Favorisez la durabilité et la sécurité dans votre laboratoire grâce à des fonctionnalités respectueuses de l'environnement, notamment des lames réutilisables économiques et des colorants de viabilité non toxiques comme l'érythrosine B.
Faible encombrement pour maximiser l'espace de travail
Un excellent choix pour les laboratoires à espace restreint, avec une largeur compacte de 16 cm (6,3 pouces) - plus petite qu'une feuille de papier standard - offrant une analyse puissante dans un encombrement réduit.
Les coûts les plus bas. La plus grande commodité.
Perfect for labs on a budget, our LUNA™ family of automated cell counters work with the LUNA™ Reusable Slide. The LUNA™ Reusable Slide delivers the affordability of manual cell counting without the associated time, subjectivity, and user-to-user variability. Our disposable slides offer the ultimate counting experience. With no mess or cleanup, these precision slides are convenient and maintain the highest standard of cell counting accuracy.
QUE DISENT NOS CLIENTS?
Testimonials
(5.0)
Marty Schoenle

Easy to use and adjust parameters for different sample types. Easy to use instrument with a small footprint. It is easy to change parameters for the most accurate cell counting for different cell types. Disposable cell counting slides allow for the rapid counting of many different cultures with easy clean-up. Customer service is also great.

Cornell University

(5.0)
Olivia H

Quick and easy – makes cell culture a breeze! Our lab relies heavily on the Luna – it’s quick and easy to use, and I know it will give me an accurate count! It’s particularly great when I’m short on time because I can simply load the settings for a protocol that I’ve created previously and then I can count multiple samples efficiently. I manually adjust the focus to get the best and most accurate results, but the interface is clear and easy to use. All of our lab members use this piece of equipment daily, and it makes a huge impact on the l ab while taking up minimal benchtop space. We highly recommend the Luna!

Boston University

Show More >
Where The LUNA-III™(LUNA-II™) Has Been Cited
Citations

Overexpression of MMPs, cytokines, and RANKL/OPG in temporomandibular joint osteoarthritis and their association with joint pain, mouth opening, and bone degeneration: A preliminary report.

2021. Cafferata EA, Monasterio G, Castillo F, Carvajal P, Flores G, Díaz W, Fuentes AD, Vernal R. Oral diseases 27(4):970–980.

Aryl Hydrocarbon Receptor is Involved in the Proinflammatory Cytokine Response to Cadmium.

2021. Kulas J, Tucovic D, Zeljkovic M, Popovic D, Popov Aleksandrov A, Kataranovski M, Mirkov I. Biomedical and Environmental Sciences 34(3):192-202.

Inertial Microfluidics-Based Separation of Microalgae Using a Contraction–Expansion Array Microchannel.

2021. Kim GY, Son J, Han JI, Park JK. Micromachines (Basel) 12(1):97.

Mitochondrial pyruvate carrier 1 regulates ferroptosis in drug-tolerant persister head and neck cancer cells via epithelial-mesenchymal transition.

2021. You JH, Lee J, Roh JL. Cancer Letters 507:40–54.

Interplay Between Nanoplastics and the Immune System of the Mediterranean Sea Urchin Paracentrotus lividus.

2021. Murano C, Bergami E, Liberatori G, Palumbo A, Corsi I. Frontiers in Marine Science https://doi.org/10.3389/fmars.2021.647394.

Show More >
Resources
Downloads
LUNA-III™
brochure

2024-09-01 | 527 KB

Download
LUNA-III™
Quick Start Guide

2024-09-01 | 255 KB

Download
Cell DB
U937
Cell counting protocol
Min. search size : 8 mm
Max. search size : 20 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
Raw264.7
Cell counting protocol
Min. search size : 8 mm
Max. search size : 20 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
McCoy
Cell counting protocol
Min. search size : 10 mm
Max. search size : 25 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
HeLa
Cell counting protocol
Min. search size : 12 mm
Max. search size : 27 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
Show More >
Informations pour commander
Cat #ProductQty
L60001LUNA-III™ Automated Cell Counter1 unit
L60002LUNA-III™ Automated Cell Counter, Sustainable Package1 unit
L12001LUNA™ Cell Counting Slides, 50 Slides1 boxes
L12002LUNA™ Cell Counting Slides, 500 Slides10 boxes
L12003LUNA™ Cell Counting Slides, 1000 Slides20 boxes
L12011LUNA™ Reusable Slide1 unit
L12012LUNA™ Reusable Slides (2 pack)2 units
L12014LUNA™ Reusable Slide Coverslips10 units
T13001Trypan Blue Stain, 0.4%2 x 1 mL
T13011Trypan Blue Stain, 0.4%, Sterile-filtered2 x 1 mL
L13002Erythrosin B Stain2 x 1 mL
B13101LUNA™ Standard Beads2 X 1 mL
P17001LUNA™ Printer II1 unit
U10005USB Drive, 16 GB1 unit
L72041Cell Counter Validation Slide-BF II1 unit
L64003LUNA-III™ IQ/OQ Protocol1 copy
Caractéristiques
Cell Counting TimeApprox. 10 s (manual focusing) Approx. 15 s (autofocusing)
Cell Concentration Range5×104 – 1×107 cells/ml
Cell Size Range3~60 μm (optimal : 8~30 μm)
Cell Viability Range0~100 %
Image Resolution5 MP
Image TypeTIF, annotated TIF
ReportPDF format
Dimensions (W×D×H)16 × 18 × 28 cm (6.3 × 7.0 × 11.0 in)
Weight1.8 kg (4 lb)  *without the AC adaptor and power cord
Operating Power100~240 VAC, 1.2 A
Frequency50/60 Hz
Electrical Input12 VDC, 3.3 A