BRIGHTFIELD CELL COUNTER
LUNA-III™ Automated Cell Counter

The LUNA-III™ Automated Cell Counter provides unmatched accuracy with advanced algorithms, precise autofocusing, reusable slides, non-toxic dyes, network access, re-analysis options, and a compact, user-friendly design.

Request Quote & Demo
Compare Counters

Introducing the LUNA-III™ Automated Cell Counter, the ultimate in cell counting technology, designed to enhance your lab's productivity and precision. Building on the proven success of the LUNA II™, the LUNA-III™ Automated Cell Counter offers an array of advanced features:

Machine Learning Optimized for Excellence
Experience unparalleled accuracy for individual cell recognition in highly aggregated samples, thanks to our state-of-the-art algorithms.
Advanced Autofocus Technology
Fast and accurate autofocusing for improved efficiency. Improved autofocus capabilities enhance cell recognition and measurement, enabling better decisions in downstream applications and protocols.
Optimal Accuracy via Reanalysis
Obtain accurate results for diverse cell types and distinctive reanalysis capabilities enabling users to refine protocols, conserve samples, and eliminate additional preparation.
Seamless and Flexible Data Management
Enjoy seamless data management with internal storage, USB support, and network connectivity, allowing easy data storage, retrieval, and transfer to computers.
Eco-Friendly Options
Promote sustainability and safety in your lab with eco-friendly features, including cost-effective reusable glass slides and non-toxic viability dyes like erythrosine B.
Small Footprint Maximizes Benchspace
An excellent choice for space-constrained labs, with a compact 16 cm (6.3 inch) width—smaller than a standard piece of paper—offering powerful analysis in a small footprint.
The Lowest Cost. The Greatest Convenience.
Perfect for labs on a budget, our LUNA™ family of automated cell counters work with the LUNA™ Reusable Slide. The LUNA™ Reusable Slide delivers the affordability of manual cell counting without the associated time, subjectivity, and user-to-user variability. Our disposable slides offer the ultimate counting experience. With no mess or cleanup, these precision slides are convenient and maintain the highest standard of cell counting accuracy.
What Do Our Customers Have To Say?
Testimonials
(5.0)
Marty Schoenle

Easy to use and adjust parameters for different sample types. Easy to use instrument with a small footprint. It is easy to change parameters for the most accurate cell counting for different cell types. Disposable cell counting slides allow for the rapid counting of many different cultures with easy clean-up. Customer service is also great.

Cornell University

(5.0)
Olivia H

Quick and easy – makes cell culture a breeze! Our lab relies heavily on the Luna – it’s quick and easy to use, and I know it will give me an accurate count! It’s particularly great when I’m short on time because I can simply load the settings for a protocol that I’ve created previously and then I can count multiple samples efficiently. I manually adjust the focus to get the best and most accurate results, but the interface is clear and easy to use. All of our lab members use this piece of equipment daily, and it makes a huge impact on the l ab while taking up minimal benchtop space. We highly recommend the Luna!

Boston University

Show More >
Where The LUNA-III™(LUNA-II™) Has Been Cited
Citations

Overexpression of MMPs, cytokines, and RANKL/OPG in temporomandibular joint osteoarthritis and their association with joint pain, mouth opening, and bone degeneration: A preliminary report.

2021. Cafferata EA, Monasterio G, Castillo F, Carvajal P, Flores G, Díaz W, Fuentes AD, Vernal R. Oral diseases 27(4):970–980.

Aryl Hydrocarbon Receptor is Involved in the Proinflammatory Cytokine Response to Cadmium.

2021. Kulas J, Tucovic D, Zeljkovic M, Popovic D, Popov Aleksandrov A, Kataranovski M, Mirkov I. Biomedical and Environmental Sciences 34(3):192-202.

Inertial Microfluidics-Based Separation of Microalgae Using a Contraction–Expansion Array Microchannel.

2021. Kim GY, Son J, Han JI, Park JK. Micromachines (Basel) 12(1):97.

Mitochondrial pyruvate carrier 1 regulates ferroptosis in drug-tolerant persister head and neck cancer cells via epithelial-mesenchymal transition.

2021. You JH, Lee J, Roh JL. Cancer Letters 507:40–54.

Interplay Between Nanoplastics and the Immune System of the Mediterranean Sea Urchin Paracentrotus lividus.

2021. Murano C, Bergami E, Liberatori G, Palumbo A, Corsi I. Frontiers in Marine Science https://doi.org/10.3389/fmars.2021.647394.

Show More >
Cell DB
U937
Cell counting protocol
Min. search size : 8 mm
Max. search size : 20 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
Raw264.7
Cell counting protocol
Min. search size : 8 mm
Max. search size : 20 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
McCoy
Cell counting protocol
Min. search size : 10 mm
Max. search size : 25 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
HeLa
Cell counting protocol
Min. search size : 12 mm
Max. search size : 27 mm
Cell detection sensitivity : 5
Live cell sensitivity : 5
Noise reduction : 5
Dilution factor : 2
Size gating :
Show More >
Ordering Information
Cat # Product Qty
L60001 LUNA-III™ Automated Cell Counter 1 unit
L60002 LUNA-III™ Automated Cell Counter, Sustainable Package 1 unit
L12001 LUNA™ Cell Counting Slides, 50 Slides 1 boxes
L12002 LUNA™ Cell Counting Slides, 500 Slides 10 boxes
L12003 LUNA™ Cell Counting Slides, 1000 Slides 20 boxes
L12011 LUNA™ Reusable Slide 1 unit
L12012 LUNA™ Reusable Slides (2 pack) 2 units
L12014 LUNA™ Reusable Slide Coverslips 10 units
T13001 Trypan Blue Stain, 0.4% 2 x 1 mL
T13011 Trypan Blue Stain, 0.4%, Sterile-filtered 2 x 1 mL
L13002 Erythrosin B Stain 2 x 1 mL
B13101 LUNA™ Standard Beads 2 X 1 mL
P17001 LUNA™ Printer II 1 unit
U10005 USB Drive, 16 GB 1 unit
L72041 Cell Counter Validation Slide-BF II 1 unit
L64003 LUNA-III™ IQ/OQ Protocol 1 copy
Specifications
Cell Counting Time Approx. 10 s (manual focusing) Approx. 15 s (autofocusing)
Cell Concentration Range 5×104 – 1×107 cells/ml
Cell Size Range 3~60 μm (optimal : 8~30 μm)
Cell Viability Range 0~100 %
Image Resolution 5 MP
Image Type TIF, annotated TIF
Report PDF format
Dimensions (W×D×H) 16 × 18 × 28 cm (6.3 × 7.0 × 11.0 in)
Weight 1.8 kg (4 lb)  *without the AC adaptor and power cord
Operating Power 100~240 VAC, 1.2 A
Frequency 50/60 Hz
Electrical Input 12 VDC, 3.3 A